AKAS Infusions Pump
PRODUCT HIGHLIGHTS :
- Compatible with all IV Sets
- Rugged Sets
- Adult/micro IV set Compatible
- Easy to Use
Security policy
Delivery policy
Return policy
AKAS syringe (infusion) pump combines high levels of safety and performance to provide a basic and reliable Operation. Akas syringe pump is designed in such a way that it offers several advanced features ideal for general, critical care, neonatal, and cancer therapy infusions where accuracy is key. At their simplest, Akas infusion Pump comprises a user interface that controls the electromechanical pumping mechanism responsible for driving fluid from a container (bag, bottle, or syringe) through flexible tubing into a patient’s catheter. Buy with us and get the best akas syringe pump price.
- External Drop Sensor Benefits -
The external drop sensor is designed to ensure that accuracy is maintained across a variety of IV sets
making our products compatible with all IV sets manufactured.
- Multi-Mode -
Our volumetric infusion pump can be used for pediatric and adult infusions as our product works
with both adult and micro IV sets.
The infusion rate can be further set in drop/min or ml/hr as per drug calculation.
- Compatible with all IV sets -
The external drop sensor allows us to calculate the volume infused accurately through drop-to-volume conversion for any IV set. This enables compatibility with all brands of IV sets.
- Intuitive Interface -
The keypad is designed in an intuitive way with LED indicators, LCD, and an organized position of
buttons to make it intuitive.
- Easy To Operate -
The IV door and the insertion mechanism are designed in a way allowing nursing staff to quickly
fix the IV tube in the section and move ahead with other roles.
PRODUCT NAME | Akas Infusion Pump |
BRAND | AKAS |
MODEL | INFU MAX |
POWER SUPPLY | AC 220V to 240V 50Hz |
BATTERY BACKUP | 4hrs@8 drops/min or 25ml/hr (Auto Power Saving Mode) |
POWER CONSUMPTION | 10VA |
PUMPING MECHANISM | Linear Peristaltic |
DROP SENSOR | External 'Air in line |
DETECTOR | Internal |
DISPLAY |
LCD and 7-segment LED Display |
SAFETY FEATURES |
Free flow protection, Excess/Less Alarm, Air in Line Protection, Sensor Malfunction Protection |
I.V SET TUBING |
Accepts all Brands of I.V set |
I.V SET ml CONVERSION |
Adult I.V sets - 12 to 26 drops/ml in steps of 0.5 Micro I.V sets - 50 to 85 drops/ml in steps of 1 |
DROP RATE RANGE |
1 to 150 drop/min for Adult 1 to 100 drop/min for Micro |
VOLUME RATE RANGE |
0.5 to 900 drop/min for Adult 0.1 to 100 drop/min for Micro |
DROP RESOLUTION | 1 drop/min |
BOLUS FUNCTION | Auto Bolus, Purge Bolus |
BOLUS RATE FLOW |
10 to 900mL/Hr - Adult 10 to 100mL/Hr - Micro |
FLOW RATE RESOLUTION |
SEQUENTIAL PRESS Adult : 0.5 to 100ml/hr Step 0.1ml/hr 100 to 900ml/hr Step 1ml/hr Micro: 0.1 to 100ml/hr Step 0.1ml/hr
PRESS & HOLD Adult : 0.5 to 100ml/hr Step 2ml/hr 100 to 900ml/hr Step 10ml/hr Micro: 0.1 to 100ml/hr Step 2ml/hr |
TARGET VOLUME | 1 to 990ml |
TARGET VOLUME STEPS |
Adult : 1 to 100ml/hr Step 1ml 100 to 900ml Step 10ml Micro: 0.5 to 10ml Step 0.1ml 10 to 100ml Step 1ml 100 to 500ml Step 10ml |
BOLUS VOLUME |
0.1 to 50mL |
ELAPSED TIME | 00:00 to 99:59 Hr |
KVO | off to 3dr/min or 3ml/hr steps 1 |
BATTERY CHARGING PERIOD | 16 HRS automatic |
BATTERY TYPE | Rechargeable Ni-Cd, Built-in & standard |
ALARM INDICATION | Target volume, Target time, Excess flow, Less flow, Air in line, Battery low, KVO |
MENU-DRIVEN | Self Guided/Help Assisted Interactive Functions, Self Diagnosis of Alarm Causes |
HOUSING | ABS plastic |
DIMENSION | 140mm * 140mm * 200mm |
WEIGHT | 2.8 KG |
CERTIFICATION | CE, ISO 13485:2003, ISO 9001:2008 |
Disclaimer
The description and specifications on the website are correct at the time of publishing.
In Pursuit of continual improvement, we reserve the right to change the design and specifications of any of our products without prior notice.
Picture for illustration purposes only. Specifications are taken from the above company website and they may change as per the changes on the company website.
Please take the advice of the authorized medical practitioner before use.